How to solve when the pressure of the crimping machine is insufficient


Time of issue:

2021-04-28

How to solve when the pressure of the crimping machine is insufficient In the work of the withholding machine, sometimes we encounter the phenomenon of insufficient pressure of the withholding machine. At this time, we need to analyze the withholding machine according to the on-site situation to eliminate related faults in time to ensure that the withholding operation continues. 1. The pump is faulty Eliminate the failure of the pump body or replace it with a new pump; 2. The pump is not adjusted to working condition; Let skilled workers re-adjust the pump; 3. Poor work or damage of the overflow valve; Repair or replace the overflow valve 4. Oil leakage of parts and components; Repair or replace the leaking part; If you still cannot find the cause after performing the above failure analysis, you must contact the manufacturer in time for further failure analysis of the equipment. 5. After the crimping machine has been used for a long period of time, there may be a phenomenon that the crimping machine cannot rebound after being compressed, which hinders the work progress. At this time, we must promptly investigate the problem according to the situation. Crimping machines are generally hydraulically driven, so there is no problem such as spring failure. The most likely problem is the solenoid valve that controls the pressure. In the case of improper maintenance, the solenoid valve may fail due to excessive oil pollution. Under normal circumstances, as long as the solenoid valve is disassembled and the dust, oil and other impurities on it are cleaned, it can be restored to work. If the problem cannot be solved, it depends on whether the solenoid valve is damaged. If it is damaged, replace the solenoid valve to solve the problem. If the related problems cannot be solved after the above operations, you should call the manufacturer of the equipment.

How to solve when the pressure of the crimping machine is insufficient
In the work of the withholding machine, sometimes we encounter the phenomenon of insufficient pressure of the withholding machine. At this time, we need to analyze the withholding machine according to the on-site situation to eliminate related faults in time to ensure that the withholding operation continues.

1. The pump is faulty

Eliminate the failure of the pump body or replace it with a new pump;

2. The pump is not adjusted to working condition;

Let skilled workers re-adjust the pump;

3. Poor work or damage of the overflow valve;

Repair or replace the overflow valve
4. Oil leakage of parts and components;

Repair or replace the leaking part;

If you still cannot find the cause after performing the above failure analysis, you must contact the manufacturer in time for further failure analysis of the equipment.

5. After the crimping machine has been used for a long period of time, there may be a phenomenon that the crimping machine cannot rebound after being compressed, which hinders the work progress. At this time, we must promptly investigate the problem according to the situation.

Crimping machines are generally hydraulically driven, so there is no problem such as spring failure. The most likely problem is the solenoid valve that controls the pressure.

In the case of improper maintenance, the solenoid valve may fail due to excessive oil pollution. Under normal circumstances, as long as the solenoid valve is disassembled and the dust, oil and other impurities on it are cleaned, it can be restored to work.

If the problem cannot be solved, it depends on whether the solenoid valve is damaged. If it is damaged, replace the solenoid valve to solve the problem.

If the related problems cannot be solved after the above operations, you should call the manufacturer of the equipment.

Keyword:

the,of,to,is,valve,it,pump,machine,solenoid,crimping,machine,hose,crimping,machine,hose,crimper,hydraulic,hose,crimper,hydraulic,hose,crimping,machine